Air Handler Return Dampers | HVAC Components - These return air dampers serve a large air handler on a rooftop. This return air damper ends up in a mixing box inside the air handler where the return air from the building mixes with the outside air from the economizer. (more…)
Variable Air Volume Systems - Variable Air Volume (VAV) systems are the best way to zone especially in large buildings. A VAV system with the proper controls and setup will help the building owner realize large savings in energy usage. There are many VAV systems out there set up in different ways. The most common set-up (for DDC) is, of course, usually the cheapest to install.
They have an air handler (DX or Chilled Water) which supplies the VAV Boxes with fixed pressure and temperature of the conditioned air. The VAV Boxes have electric reheat which will heat the air if that particular zone calls for heat (it is not uncommon to also find VAV boxes that have hot water reheat although this usually costs more to install but can save in energy costs). More on how VAV boxes work.
Alerton BTI DDC Controller Building Automation - This is the main DDC controller for Alerton. It communicates with all the other controllers in the field serving the building automation system and connects those systems with a computer or modem. (more…)
In HVAC a variable speed drive is a speed control system for electric motors. The variable speed drive (VSD) or variable frequency drive (VFD), among other names (adjustable-frequency drives (AFD), AC drives, micro-drives, or inverter drives). The application of variable speed drives has brought about a new way of engineering buildings and control systems HVAC.
The flow of water and air can now be regulated precisely using VSD’s and state-of-the-art control systems. By combining VSD’s with state-of-the-art control systems, large savings in energy usage can see realization because the exact quantity of flow of water or air can be delivered to satisfy demand.
Demand-based control is energy efficient. VSD’s can be stand-alone or controlled by a building automation system.
DDC Programming Logic 3 - DDC control logic blocks have practically an unlimited way of arranging the blocks for HVAC control. Below is an example of a line of logic blocks arranged for static pressure control of a VAV air handler supply fan using a variable frequency drive. This same arrangement could also be used for static pressure control using a bypass damper instead of a VFD. (more…)
Programming DDC Logic 2 - The analog network input is similar to an analog input except this input is not hardwired to the local controller but on a remote controller in the network. It is very important that the communication works effectively for this analog network input to work. An example of this is the outside air temperature which is hardwired to a DDC controller in the penthouse of a multistory building.
The building engineer only wants the boilers to fire if the outside air temperature is less than 55° F. Instead of having an outside air temperature device hardwired to the boiler controller an analog network input can be placed into the boiler controller program and linked to the outside air temperature reading which is in the penthouse controller where the outside air temperature thermistor is hardwired. This saves devices and wires necessary for optimum control.
Air Handler Components. This article will take different types of air handlers and disassemble them part by part. This will give you a good description of each part and hopefully a better understanding of the air handler. Most of the components associated with the air handler are in the air handler. However, there are a few components which are not in the air handler but associated with the air handler.
There are some hot water and cold water coils which are not fixed in the air handler. They are downstream in the ductwork. There are also some gas and electric duct heaters which are mounted in the ductwork. They are completely reliant on the air handler for air flow. These systems will also be covered. Hopefully, this article will offer you a comprehensive look at the air handler, all its parts, and how it functions. (more…)
Air Handler Filter Pressure Sensor - This is a pressure sensor. It tells a maintenance technician if the air filters are dirty and clogged. The pressure control is a low static pressure switch to trip the unit if the mixing box drops below the setpoint pressure. The pressure the switch is calibrated to.
In addition, the low static pressure sensor protects the fan and the ductwork including dampers from damage. If the economizer damper and the return air damper would fail closed (or another possible scenario) that would cause the unit to pull negative pressure in the mixing box. (more…)
Most air conditioning and heating systems require some form of ductwork. Ductwork channels or directs the air to places in the dwelling where the conditioned air is needed. There are many types of ductwork available. Often times the ductwork can make a big difference in your utility bills. For that reason, it is important that the ductwork is installed correctly by qualified installation technicians. (more…)
York VAV Air Handlers | HVAC Zoning - This York air handling unit serves several VAV boxes and runs on a static pressure control set point determined by a DDC program. This program has a static pressure control setpoint and sends a signal to the variable frequency drive to speed up or slow down the blower to maintain the proper static pressure control setpoint. When the VAV boxes need more air the drive speeds the air handler blower up.
When the VAV boxes need little the drive slows the blower down. The VAV boxes are controlled by a thermostat in their respective zones.
HVAC Tip - Ceiling Fans Save Energy: Ceiling fans installed strategically in your home or business can save you in air conditioning energy costs in the summer. The draft effect from the fan will allow you to raise the thermostat setting by up to 4 degrees and still remain comfortable. Make sure you purchase ceiling fans with energy efficient motors and blade designs. Some ceiling fans have inefficient motors and bad blade designs that will reduce the energy savings you can realize. A qualified electrician can install ceiling fans in your home or business and you can enjoy the savings and compliment your HVAC system.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.