by High Performance HVAC | Boilers |

Outside All Weather Boiler - Outside all-weather boilers are used in circumstances where it is not possible to install the boiler inside a mechanical room or anywhere in the building. There some considerations one needs to take into account about having an outdoor boiler especially if it is for a residential application. (more…)
by High Performance HVAC | Air Handlers |
Air Handler Components. This article will take different types of air handlers and disassemble them part by part. This will give you a good description of each part and hopefully a better understanding of the air handler. Most of the components associated with the air handler are in the air handler. However, there are a few components which are not in the air handler but associated with the air handler.
There are some hot water and cold water coils which are not fixed in the air handler. They are downstream in the ductwork. There are also some gas and electric duct heaters which are mounted in the ductwork. They are completely reliant on the air handler for air flow. These systems will also be covered. Hopefully, this article will offer you a comprehensive look at the air handler, all its parts, and how it functions. (more…)
by High Performance HVAC | Boilers |

The automatic air vent is found in the piping system of water loops. If air is introduced into the water loop system it eventually finds its way to the automatic air vent where it is vented. The automatic air vents are located throughout the system. Automatic air vents may also be found throughout any hydronic loop system. A hydronic loop is a water loop.
These water loops can be for hot water or chilled water. Any hydronic loop needs an air management system or automatic air bleeder system to keep the air out of the system otherwise, the air will be up in the system and air will block or prevent the flow of water throughout the loop. Water naturally has air in it. Air vents help the water loop by: (more…)
by High Performance HVAC | Air Handlers |
York Air Handling Unit Chilled Water Coil - This coil is a cooling coil in a large commercial York air handling unit. The air handler serves approximately 80 VAV boxes and is responsible for providing cool conditioned air to all the zones the VAV boxes serve based on a set point determined in a DDC program and the chilled water coil seen here. (more…)
by High Performance HVAC | Boilers |
Boiler Supply and Return Piping - Any heating pipe system will experience a heat loss in the pipe even when the pipe is insulated. The loss is far greater when the pipe is uninsulated. Good boiler piping insulation will reduce the heat loss experienced in the pipe run throughout the loop especially where the pipe runs in unconditioned or unheated spaces where heating is not necessary.
Boiler Supply and Return Piping
Good Supply and Return Insulated Pipe will increase the efficiency of the boiler and reduce overall the heat loss of the entire system as a whole throughout the heating season. Insulate exposed piping wherever you find it and replace old insulation that is falling off. Be careful to identify the correct insulation and never ever disturb asbestos insulation. Asbestos is dangerous especially if you breathe in the particles from it. A professional asbestos remediation company must be hired to remove it safely.