Ductwork and High Ceilings - I did not see any reference to my question and would appreciate a response as soon as possible, as due to a medical situation, have to make a decision soon. We own an OLD house with 13′ ceilings in a large part of the home and 11″ ceilings in the LV/DR and BR. We are oscillating on where to place the ducts…Floor or ceiling. It appears to be counterproductive to me to put the ductwork in the ceiling since it will have so far to go.
We are looking for the most cost-effective, not upfront cost but operating cost, solution. In addition, we are considering DF heat pumps. The house will need 2 or 3 to be zoned correctly. Please let me know about the duct placement and thank you for your help? (more…)
This chilled water unit is a new ammonia chiller. This unit is also unique in that it has no compressor. Instead, it uses the chemical properties of ammonia and heat from natural gas to condense the refrigerant which is ammonia. A chiller provides chilled water to a chilled water loop. (more…)
VAV Air Handlers are ideal for providing zones in a commercial building. Office space typically has several offices and open areas that need to be conditioned for the comfort of the people working in those areas or offices. By installing VAV boxes and zoning the ductwork from those VAV boxes these areas and offices can be kept comfortable using a VAV air handler system. More on how VAV boxes work. (more…)
VAV Box Types Fan Powered and Shut Off VAV Boxes - When attempting to name the different types of VAV boxes we find there are different names given to VAV boxes by different people and we find that no one is on the same page when VAV boxes are definitively defined.
We have fan-powered VAV and non-fan-powered VAV’s and we have series and parallel VAV’s and we have VAV boxes with a hot deck and a cold deck that mixes and one of the last projects I worked on some of the VAV’s were referred to as shut-off vavs. Variable Air Volume Boxes (VAV Boxes) regulates airflow into zones using a primary air source from a VAV air handler.
VAV Box Types Fan Powered and Shut Off
Cool only single ducted series
Fan-powered single duct series with reheat
Fan-powered single ducted parallel with reheat - uses plenum air before using reheat for energy efficiency
Aside from the control aspect of VAV boxes, pneumatic, electric, electronic, or DDC, there are many different variations to VAV Boxes and we will attempt to define each type of VAV including offering a diagram of each type and matching it with a specific application. VAV boxes are simply an assembly of a damper, damper controls, and sometimes reheat such as electric heat strips or a hot water coil. VAV boxes get their primary air source from a central VAV air handler and then distribute air throughout a specific zone the VAV box controls.
Air Handler Unit Construction Phase | HVAC AHU - Air Conditioning and Heating AHUs provide air flow throughout the duct systems providing conditioned air throughout the spaces served by the duct work. Air conditioning and heating systems rely on air handlers to move the air throughout the system. The HVAC AHU also conditions the air. The air handler heats air for heating and cools air for air conditioning. (more…)
Air Conditioner Squirrel Cage Blower | HVAC blower motors move the air through the system. The blower motor is sized based on the amount of air flow necessary for the system. This blower motor is the supply fan for the supply air in a large commercial York AHU. An AC and heatingforced air system is sized based on load. The load factors include heat loss and heat gain, number of people in the building, types of rooms served, factoring in heat produced by equipment such as computers and other heat producing equipment. (more…)
Variable Air Volume Systems - Variable Air Volume (VAV) systems are the best way to zone especially in large buildings. A VAV system with the proper controls and setup will help the building owner realize large savings in energy usage. There are many VAV systems out there set up in different ways. The most common set-up (for DDC) is, of course, usually the cheapest to install.
They have an air handler (DX or Chilled Water) which supplies the VAV Boxes with fixed pressure and temperature of the conditioned air. The VAV Boxes have electric reheat which will heat the air if that particular zone calls for heat (it is not uncommon to also find VAV boxes that have hot water reheat although this usually costs more to install but can save in energy costs). More on how VAV boxes work.
HVAC Damper Actuator for Economizer Free Cooling - This damper actuator controls a free cooling damper for an economizer. It is part of an economizer damper system which allows free outside air cooling when the outside air temperature and humidity are ideal. In the Fall and the Spring when the outside air temperatures are mild it is unnecessary to run the air conditioning system to cool the building if the system is set up for free cooling. (more…)
HVAC Duct Work delivers the conditioned air to the spaces. The Air Handling Duct channels this conditioned air to spaces where it is needed and then a return duct channels the air back to the air handling unit duct for re-conditioning. The return ductwork has a negative pressure while the supply ductwork has positive pressure.
In commercial systems and tight residential homes, it is necessary to add fresh air to this conditioned air so the air remains fresh and healthy for the occupants of the structure. This is required by the mechanical code and often this air comes through ductwork from the outside. (more…)
Most air conditioning and heating systems require some form of ductwork. Ductwork channels or directs the air to places in the dwelling where the conditioned air is needed. There are many types of ductwork available. Often times the ductwork can make a big difference in your utility bills. For that reason, it is important that the ductwork is installed correctly by qualified installation technicians. (more…)
HVAC Tip - Carbon monoxide detectors are important to own for those people who burn fossil fuels for heat. Carbon monoxide is a flammable, colorless, odorless, tasteless toxic gas produced during incomplete combustion of fuel - Natural Gas, Oil, Coal, Wood, Kerosene, etc. Someone suffering from carbon monoxide poisoning generally has severe headaches, nausea, and sinus problems. These symptoms generally begin with mild effects and people usually remain unaware of what the exact problems are until, sometimes, it is too late. How many cracked heat exchangers or faulty furnaces are out there that no one knows anything about except a slight headache and nausea? Don't take any chances, get your carbon monoxide detector and call your local heating and air conditioning company for a heater inspection today. Read more on this subject on the Furnace Page.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.