Honeywell VisionPro Heat Pump Thermostat Review

Honeywell VisionPro Heat Pump Thermostat - Programming and SettingsHoneywell VisionPro Heat Pump Thermostat Review: Richard, I have a Honeywell Vision Pro Programmable Thermostat. I was wondering how I can program the settings to save money? It was recently installed six months ago and I want to make sure it is programmed to get the best out of it for a heat pump.

At this point, I do not believe I have saved money and was told I could save 10% or more with a programmable thermostat. Please help me with the appropriate settings and give me some insight that would help me save money. Thank you and I look forward to your answer. (more…)

White Rodgers and Honeywell Thermostats | Thermostat Selection

White Rodgers and Honeywell Thermostats | Thermostat SelectionWhite Rodgers and Honeywell Thermostats - Which type and brand of thermostat do you get when selecting a new thermostat? To do that you have to know what kind of HVAC system you have installed for your heating and cooling system. Do you have a hot water boiler with baseboard heating or radiators with the boiler combination?

In addition to the boiler do you have an air conditioning system with ductwork or a mini-split ductless system? Do you have a heat pump system? Do you have electric baseboard heating? Do you have an air conditioner system with electric heat? It is important to know the answers to what kind of HVAC system you have installed in your home. (more…)

Electronic Ignition Gas Furnace Problems Troubleshooting

Electronic Ignition Gas Furnace Problems Troubleshooting

White Rodgers Gas Furnace Ignition Control Board

Electronic Ignition Gas Furnace Problems Troubleshooting - Gas furnaces are a prevalent form of heat for homes and businesses, and occasionally a gas furnace needs to be repaired because of a problem with the gas furnace.

Since there are many different types of gas furnaces, it is difficult to cover every single possible gas furnace problem that can occur with a gas furnace in one article. We are going to break this theme “gas furnace problems” down into a series of articles with the first one being gas furnace problems with electronic ignition gas furnaces.
(more…)

Wireless WIFI Smart Thermostats | HVAC Control

wireless wifi smart thermostatsWireless WiFi Smart Thermostats - The future of wireless thermostats have already arrived as there are a handful of wireless thermostats available on the market now. These are the forefathers of wireless thermostats and offer basic functions that the average wired programmable thermostat has to offer that are currently available on the market.

As we progress and the thermostat manufacturers tweak and improve on their thermostats, the thermostats will grow far more complex than the wireless thermostats offered today. This new breed of the wireless thermostat is a far cry from the once state-of-the-art thermostats that offered touch screens and adaptive recovery features that the current breed of thermostat offers.

As we move into the future, we see new features and options that will offer us more control, monitoring, and energy savings. All the manufacturers have something in the pipeline for wireless thermostats including Venstar, Emerson (White-Rodgers), and Honeywell to name a few thermostat manufacturers. (more…)

Changing a Standing Pilot Boiler to Electronic Ignition – Conversion Upgrade

Changing a Standing Pilot Boiler to Electronic Ignition

The Honeywell Y8610U Intermittent Pilot Retrofit Kit

Changing a Standing Pilot Boiler to Electronic Ignition - Conversion Upgrade - How many times have you spent time in the cold trying to light a pilot light on a standing pilot gas system?

I am certain if you are a service technician, then the previous sentence can be qualified with “How many frustrating times.” You go on a service call and find the old standing pilot gas system. Whether it is a water heater, furnace, or boiler, and you find the thermocouple is bad. Or some other reason that is keeping the pilot light from staying lit.

You clean the pilot burner and replace the thermocouple and walla…………..it lights and stays lit. The magical standing pilot works again. There is another option for you and your customer. And while it is not recommended in every situation it can help eliminate those pesky repeat service calls.

Calls where the pilot continues to go out for whatever reason? The sudden ghostly draft is one of the big reasons. Honeywell produces an electronic ignition retrofit kit that is ideal for residential and light commercial gas furnace systems. Gas systems that are eligible for an upgrade from standing pilot to electronic ignition (covers BTU ratings up to 270,000).

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

Changing a Standing Pilot Boiler to Electronic Ignition | Conversion Upgrade

The Y8610U Intermittent Pilot Retrofit Kit from Honeywell comes complete. It comes with a gas valve (Natural Gas to Propane (LP)) conversion kit in the box), ignition control, electronic spark assembly with flame sensor, ignition wire, and wiring harness. A seasoned technician will find wiring this a snap. Out of the box the gas valve can be used with either ½” or ¾” pipe so this will work with little changes made to the gas pipe.

From Standing Pilot to Electronic Ignition - Changing a Standing Pilot Boiler to Electronic Ignition

I recently upgraded my boiler from a standing pilot to this electronic ignition control. It reminded me of all those standing pilot furnaces and boilers out there that have been changed to electronic ignition by me when I was working in the field. I had recently purchased a new – old house (1920) that has a steam boiler in the basement. All summer, I kept thinking about upgrading the boiler to electronic ignition from a standing pilot.

Especially after a nasty springtime encounter with lighting the pilot light that reminded me of all the frustrating experiences. Finally, fall arrived, and it was time to start up the old boiler so we can have some heat. That is when I ordered the Y8610U Intermittent Pilot Retrofit Kit.

Throwing the Switch - Changing a Standing Pilot Boiler to Electronic Ignition

The intermittent pilot retrofit kit arrived, and immediately, I took it down to the boiler to make the new introduction. About an hour and a half later, I threw the switch for the main power. The boiler and the new electronic ignition module came to life by sparking. I couldn’t see it, but I could hear it.

About a second or two of sparking and I heard the pilot fire. A second later, the main burner’s fired and the old boiler (approximately 30 years old) got a taste of modern technology. Another hour in the basement was taking care of the boiler and doing annual boiler maintenance, and I can feel comfortable. Comfortable with the reliable heat this winter and the colder days of fall and spring.

Installation Made Easy by Honeywell

The manifold side of the gas valve is a ½ inch, but the kit comes with a ¾ inch flange if the manifold side of the gas valve requires ¾ inch. The gas supply side of the gas valve is a ¾ inch, but Honeywell includes a ¾ inch to ½ inch reducer bushing.

That makes it possible to use the include gas valve for either ¾ inch pipe or ½ inch black iron pipe. The most difficult part of the installation for me is usually not the piping or even the wiring but getting the pilot burner in the correct position to light the main burners.

The pilot burner is usually installed in a tight space, and you have to get it exactly right, so the main gas burners light right away when the main valve in the gas valve opens to feed gas to the main burners. We do not want any “whoosh” main burner ignition.

That means the pilot light is too far away from the main burner. That allows gas build-up, which can be dangerous. Make sure you get the pilot light in the recommended position per the manufacturer’s recommendations or guidelines.

Installation Tips

A few installation tips and features include the control only needs to be supplied with 24 VAC – no line voltage needed – you tap into the 24-volt transformer that should be with the boiler. Make sure you wire through all the safeties, so the control loses power when one of the safeties trips.

When the controller loses power, the burner shuts down. Always follow all the instructions when installing anything. Good luck with any future upgrades you decide to make concerning this retrofit ignition control kit.

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

High Performance HVAC

Changing a Standing Pilot Boiler to Electronic Ignition