Two-Stage Gas Furnace Buyer Tips - Two-stage gas furnaces make up over 30% of all gas furnaces installed in residences in the USA. Two-Stage gas furnaces are more efficient than single-stage gas furnaces in most cases. When purchasing furnaces always check the ARI website for and efficiency ratings and comparisons. (more…)
Variable Speed ECM Condenser Fan Motors are used in condensers for the high efficient models so that the fan speed for the condenser can be modulated according to the load of the system. The ECM variable-speed fan motors are used in condensers that have a modulating compressor. They are also used in condensers that have two compressors or two-stage compressors. The ECM motor adds to the efficiency of the system by modulating the condenser fan motor. The speed matches the compressor that runs based on demand. (more…)
An ECM Variable Speed Blower Motor in a squirrel cage blower
Variable Speed ECM Blower Motors - Variable speed ECM blower motors have become increasingly popular in residential air conditioning and heating systems. From an engineering perspective, these motors increase the efficiency of the systems and offer a whole range of other benefits that help the system and the consumer. Furthermore, comfort is enhanced using ECM blower motors along with noise reduction. (more…)
What you will learn from the Condenser Fan Motor Repair article: 1) Specific description of a motors job along with some technical details 2) Air Conditioner & heat pump fan motor operation 3) fan motor troubleshooting basics 4) Condensing unit fan motor repair warning and disclaimer - Turn the power off before working on the fan 5) Replacing or repairing the motor 6) Why you should replace the capacitor when you replace the motor 7) Conclusion along with lots of resources and related links so you can take a closer look and learn more. (more…)
This Goodman 13 SEER Heat Pump condensing unit is a new installation. The inside Goodman air handler attached to the heat pump condenser via line set was also replaced. It was replaced with this new Goodman heat pump. It’s not a good idea to put a new high SEER air conditioner or heat pump condenser without matching it. It should be matched with a properly rated and efficient air handler especially the coil. (more…)
Gas Furnace Components 3 - Gas furnace ignition controls vary from furnace manufacturer to furnace manufacturer. Some are proprietary and some are from an engineering company that specializes in gas furnace ignition controls. Honeywell being a major manufacturer of controls for HVAC also makes several gas furnace ignition controls.
Gas furnace ignition controls have advanced by leaps and bounds over the last 20 years. The standard was standing pilot ignition. Solid-state ignition controls are safer and more efficient than ignition controls of yesteryear. (more…)
What you will learn in the Thermostat Wiring Colors Code article:
First, what thermostat wire colors is likely to go to which terminal on the thermostat in your heating and cooling system
Secondly, the function of each wire terminal on the average thermostat highlighting some of the differences in those HVAC system functions from manufacturer to manufacturer as recommended for thermostat wire color
Always follow the thermostat manufacturer’s instructions whenever changing the thermostat. Always turn the power off at the air handler and the condenser and make sure there is no voltage at the transformer before proceeding.
Furthermore, the thermostat wire colors below are the most likely colors used for most installations; however, your thermostat wire colors may be different than what the indication is here. There is no official standard for thermostat wire colors. Additionally, thermostat wiring colors are not standardized. However, these are the most wiring methods used based on my years of experience in the HVAC field, where I successfully wired a lot of thermostats and as recommended by manufacturers and common sense for thermostat wiring colors code.
For instructions on how to wire a thermostat, please see how to wire a thermostat page. Refer back to this page for thermostat wire colors.
Heat Pump Frost Ice Buildup. Hi. I noticed that one of my outside heat pump condensing units was laboring throughout the night. This morning I found ice frost buildup on the heat pump condenser fins. I live in Tucson, Az. It has been colder than normal (below freezing) with a bit more moisture in the air than usual as of late.
Can you please tell me what causes this frost ice buildup, and how I go about rectifying it? Does this mean that the condenser pump is shot? I’m originally from the Midwest and have never experienced this before. What should I be doing? Thank you for your help. (more…)
HVAC Tip - Some people refer to refrigerant as Freon. So when something is wrong with their HVAC system they say, “I have a Freon leak”. Freon is a name trademarked by Dupont for R-22. R-22 is being phased out because it contains chlorine. While Freon will soon be a thing of the past, the name Freon has found its way in our lexicon as a reference to refrigerant, any type of refrigerant.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.