Air Handler Filter Pressure Sensor - This is a pressure sensor. It tells a maintenance technician if the air filters are dirty and clogged. The pressure control is a low static pressure switch to trip the unit if the mixing box drops below the setpoint pressure. The pressure the switch is calibrated to.
In addition, the low static pressure sensor protects the fan and the ductwork including dampers from damage. If the economizer damper and the return air damper would fail closed (or another possible scenario) that would cause the unit to pull negative pressure in the mixing box. (more…)
York VAV Air Handlers | HVAC Zoning - This York air handling unit serves several VAV boxes and runs on a static pressure control set point determined by a DDC program. This program has a static pressure control setpoint and sends a signal to the variable frequency drive to speed up or slow down the blower to maintain the proper static pressure control setpoint. When the VAV boxes need more air the drive speeds the air handler blower up.
When the VAV boxes need little the drive slows the blower down. The VAV boxes are controlled by a thermostat in their respective zones.
York Air Handling Unit Chilled Water Coil - This coil is a cooling coil in a large commercial York air handling unit. The air handler serves approximately 80 VAV boxes and is responsible for providing cool conditioned air to all the zones the VAV boxes serve based on a set point determined in a DDC program and the chilled water coil seen here. (more…)
York Variable Frequency Drives VFDs | HVAC Control - Variable Frequency Drives or VFDs have added a whole new dimension to energy efficiency and control. These drives, or VFDs, are hooked up to two different York VAV air handlers that have two three-phase motors a piece. (more…)
HVAC Tip - Air Conditioner & Heat Pump Tips: Additional Helpful Hints:
Always change your air filter on a monthly basis
Make sure all your supply vents are open and unobstructed
Keep area clean around indoor unit especially the return grills
Keep outdoor units free of leaves, grass, and debris including trash cans and/or children's toys or playthings like small plastic pools or playhouses.
Additionally your service technician will appreciate you not planting holly bushes near the outside unit
Lastly have system serviced every six months - once for heating and once for cooling before the season starts
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.