Electronic Ignition Gas Furnace Problems Troubleshooting

Electronic Ignition Gas Furnace Problems Troubleshooting

White Rodgers Gas Furnace Ignition Control Board

Electronic Ignition Gas Furnace Problems Troubleshooting - Gas furnaces are a prevalent form of heat for homes and businesses, and occasionally a gas furnace needs to be repaired because of a problem with the gas furnace.

Since there are many different types of gas furnaces, it is difficult to cover every single possible gas furnace problem that can occur with a gas furnace in one article. We are going to break this theme “gas furnace problems” down into a series of articles with the first one being gas furnace problems with electronic ignition gas furnaces.
(more…)

How to Hook Up a Home Thermostat | HVAC Control

How to Hook Up a Home Thermostat - If you need to install a new thermostat then you have found the right place to learn. Below we will describe to you how to hook up a new digital thermostat. Whether the old thermostat is bad or not if you simply want to replace your old one and hook up a new one. First of all, the first thing you need to take into consideration is to select the right replacement thermostat.

To select the correct replacement you need to know what kind of HVAC equipment you have in your home. Or where you want to hook up the new thermostat.  There are numerous types of air conditioner and heating combinations. Therefore, to simplify things, we will cover a basic gas furnace and air conditioner split system HVAC system. For hooking up a new thermostat similar systems to the air conditioner/gas furnace combination would be: (more…)

Changing a Standing Pilot Boiler to Electronic Ignition – Conversion Upgrade

Changing a Standing Pilot Boiler to Electronic Ignition

The Honeywell Y8610U Intermittent Pilot Retrofit Kit

Changing a Standing Pilot Boiler to Electronic Ignition - Conversion Upgrade - How many times have you spent time in the cold trying to light a pilot light on a standing pilot gas system?

I am certain if you are a service technician, then the previous sentence can be qualified with “How many frustrating times.” You go on a service call and find the old standing pilot gas system. Whether it is a water heater, furnace, or boiler, and you find the thermocouple is bad. Or some other reason that is keeping the pilot light from staying lit.

You clean the pilot burner and replace the thermocouple and walla…………..it lights and stays lit. The magical standing pilot works again. There is another option for you and your customer. And while it is not recommended in every situation it can help eliminate those pesky repeat service calls.

Calls where the pilot continues to go out for whatever reason? The sudden ghostly draft is one of the big reasons. Honeywell produces an electronic ignition retrofit kit that is ideal for residential and light commercial gas furnace systems. Gas systems that are eligible for an upgrade from standing pilot to electronic ignition (covers BTU ratings up to 270,000).

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

Changing a Standing Pilot Boiler to Electronic Ignition | Conversion Upgrade

The Y8610U Intermittent Pilot Retrofit Kit from Honeywell comes complete. It comes with a gas valve (Natural Gas to Propane (LP)) conversion kit in the box), ignition control, electronic spark assembly with flame sensor, ignition wire, and wiring harness. A seasoned technician will find wiring this a snap. Out of the box the gas valve can be used with either ½” or ¾” pipe so this will work with little changes made to the gas pipe.

From Standing Pilot to Electronic Ignition - Changing a Standing Pilot Boiler to Electronic Ignition

I recently upgraded my boiler from a standing pilot to this electronic ignition control. It reminded me of all those standing pilot furnaces and boilers out there that have been changed to electronic ignition by me when I was working in the field. I had recently purchased a new – old house (1920) that has a steam boiler in the basement. All summer, I kept thinking about upgrading the boiler to electronic ignition from a standing pilot.

Especially after a nasty springtime encounter with lighting the pilot light that reminded me of all the frustrating experiences. Finally, fall arrived, and it was time to start up the old boiler so we can have some heat. That is when I ordered the Y8610U Intermittent Pilot Retrofit Kit.

Throwing the Switch - Changing a Standing Pilot Boiler to Electronic Ignition

The intermittent pilot retrofit kit arrived, and immediately, I took it down to the boiler to make the new introduction. About an hour and a half later, I threw the switch for the main power. The boiler and the new electronic ignition module came to life by sparking. I couldn’t see it, but I could hear it.

About a second or two of sparking and I heard the pilot fire. A second later, the main burner’s fired and the old boiler (approximately 30 years old) got a taste of modern technology. Another hour in the basement was taking care of the boiler and doing annual boiler maintenance, and I can feel comfortable. Comfortable with the reliable heat this winter and the colder days of fall and spring.

Installation Made Easy by Honeywell

The manifold side of the gas valve is a ½ inch, but the kit comes with a ¾ inch flange if the manifold side of the gas valve requires ¾ inch. The gas supply side of the gas valve is a ¾ inch, but Honeywell includes a ¾ inch to ½ inch reducer bushing.

That makes it possible to use the include gas valve for either ¾ inch pipe or ½ inch black iron pipe. The most difficult part of the installation for me is usually not the piping or even the wiring but getting the pilot burner in the correct position to light the main burners.

The pilot burner is usually installed in a tight space, and you have to get it exactly right, so the main gas burners light right away when the main valve in the gas valve opens to feed gas to the main burners. We do not want any “whoosh” main burner ignition.

That means the pilot light is too far away from the main burner. That allows gas build-up, which can be dangerous. Make sure you get the pilot light in the recommended position per the manufacturer’s recommendations or guidelines.

Installation Tips

A few installation tips and features include the control only needs to be supplied with 24 VAC – no line voltage needed – you tap into the 24-volt transformer that should be with the boiler. Make sure you wire through all the safeties, so the control loses power when one of the safeties trips.

When the controller loses power, the burner shuts down. Always follow all the instructions when installing anything. Good luck with any future upgrades you decide to make concerning this retrofit ignition control kit.

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

High Performance HVAC

Changing a Standing Pilot Boiler to Electronic Ignition

Natural Gas Properties and Furnace Heating Efficiency

Natural Gas Properties and Furnace Heating Efficiency

Natural Gas Regulators

Natural Gas Properties and Furnace Heating Efficiency - Natural Gas is a popular fuel used for heating systems in America and other countries. If we look at the properties of natural gas and the heating efficiency of natural gas furnaces we will see that natural gas furnaces lose efficiency because of what is contained in natural gas as it is delivered to your home for consumption by your natural gas furnace.

Natural gas in its raw form coming straight from the ground needs to be refined to remove impurities that should not be contained in natural gas. As you read below you will see that in the refining process moisture is removed from the natural gas however during the refining process some of the moisture in the natural gas remains and therefore this affects the efficiency of your natural gas furnace.
(more…)

Honeywell Gas Furnace Ignition Control Modules | HVAC Heating

honeywell gas furnace controlsHoneywell Gas Furnace Ignition Control Modules | HVAC Heating. There are many different types of gas furnace ignition control modules that control a gas furnace or gas boiler. These solid-state control modules can easily be retrofitted to replace other control modules. In some cases, printed circuit boards in case of failure. The key is to replace the failed module or furnace control board with a new control module that will offer the correct sequence of operation.

A gas furnace ignition control module that matches the same ignition components. One of the largest manufacturers of gas furnace and gas boiler ignition controls is Honeywell. The gas ignition control modules offered by Honeywell include the following modules:

(more…)

Blank Display on Thermostat Problem – Screen Disappeared

Blank Display on Thermostat Problem
Blank Display on Thermostat Problem - Screen Disappeared - The thermostat display is our interface with our HVAC equipment. The display lets us know what the temperature is in the house. The display tells us what the desired settings are including letting us know the setpoint setting the temperature.

Some displays give us time, and the newer modern displays show us family photos like a screensaver on our computer. But what happens when the display is not there, or there is a blank thermostat display or no display on the thermostat?

Is it a bad thermostat or something else that caused the display to disappear? What do you do when the thermostat screen is not working? (more…)

Gas Oil Vent Flue Vents Materials Table | HVAC Heating

Gas Oil Vent Flue Vents Materials Table - Gas and oil vent flue piping uses different types of materials depending on the applications. It is important that gas or oil flue vent pipes are installed correctly and maintained throughout the life of the furnace

This pipe has a condensation problem which an adept technician will recognize and take corrective action before the corrosive effects of condensed gas residue eat through the flue pipes and weaken masonry in chimneys.

(more…)

How To Light a Pilot Light – HVAC Heating

Steps to Light a Pilot Light

  1. Determine That You Actually Have a Standing Pilot Gas System
  2. Check to Make Sure You Have Fuel
  3. Understand the Valve Function
  4. Light the Pilot Light
  5. Enjoy the Warmth

How To Light a Pilot Light

How To Light a Pilot Light – Standing pilot gas furnaces and water heaters are still around today even in newer homes. All the major hardware stores and HVAC dealers carry standing pilot appliances. Although a new standing pilot gas furnace or boiler is rare finds these days. Because of the move to higher efficiency models and the wide use of electronic ignition technology which improves efficiency.

Before you proceed you’ll want to determine if you actually have a standing pilot system in your HVAC furnace, boiler, or water heater.

In many cases, on many appliances, there are basic instructions on lighting it, in fact, you do have a standing pilot system. Check around the main panel or look at the gas valve itself. Sometimes, especially on older appliances, there are no instructions on it if the pilot light goes out on a standing pilot gas furnace, boiler, or water heater.

The label or sticker on the furnace, boiler, or water heater faded a long time ago and you will need to follow the instructions in this article. (more…)

How to Wire a Thermostat | HVAC Control

What You Will Learn from this How to Wire a Thermostat Article:

  1. the most common trouble call by service and repair HVAC companies
  2. about thermostat wire with a resource for more information
  3. the best advice for changing your thermostat
  4. the most common mistakes made by DIY thermostat changers
  5. the importance of identifying the type of HVAC system you have so you will select the proper thermostat.
  6. advisory and disclaimer for installing a new thermostat
  7. list of tools commonly needed to install a new thermostat
  8. step by step instructions on changing your thermostat along with hints and tips for making the job easier
  9. lots of extra links to other articles to make sure you completely understand everything you need to know. (and more about thermostats, thermostat wire, and installing a new thermostat)
  10. Resource to color codes to make it easier for installation.
  11. some thermostat wire diagrams at the end of the article
  12. You can save energy for your heating and cooling system by installing an energy-saving 7-day programmable thermostat or a setback thermostat.
  13. lots of comments from our readers
  14. thermostat wiring instructions are good for most low voltage room thermostats including a smart thermostat.

(more…)

Gas Furnace is Making Too Much Noise | Diagnosis and Repair

Gas Furnace is Making Too Much Noise – The FixGas Furnace is Making Too Much Noise - Richard, my gas furnace makes a lot of noise when it is running and it is somewhat annoying and sometimes bothers me when I am sleeping. It is installed in a closet close to my bedroom. What can I do to fix this gas furnace that is making too much noise? I’m growing to hate my noisy gas furnace. Jenny

Jenny, sorry to hear about the noise your gas furnace is making. I know an overly noisy gas furnace can be irritating. All gas furnaces make some noise when operating and we can break it down into three different noises. Depending on which noise your furnace is making will depend on a fix to your furnace making too much noise. (more…)