Air Conditioning and Heating Sizing | HVAC Technical

Air Conditioning and Heating Sizing
Air Conditioning and Heating Sizing - It is not uncommon for HVAC estimators or HVAC contractors to use various rudimentary techniques, which are generally referred to as rules of thumb. Some will say on the low end you need 1 ton of cooling for every 500 square feet.

On the high end, you will need 1 ton of cooling for every 700 square feet. These rules of thumb will also generally take into account a basic heat gain calculation for the kitchen and the number of people who will occupy the structure. (more…)

HVAC Fire Safety | Health Job & Work Safety

HVAC Fire Safety
HVAC Fire Safety - I’m not sure how many HVAC technicians have heard of on-the-job horror stories. Whether the job was commercial or residential. However, I am certain they have happened as I have heard of these horror stories happening to others.

Whether you have ever heard of it happening to others or even if it has happened to you it is important that we remain forever vigilant. This is absolutely true when it comes to fire safety on the job. Especially when we are constantly using fire as a part of our job.

And especially for silver soldering (brazing), soft soldering, or even when we are working on gas or oil boilers or furnaces. Here is an account of a few things that I’ve personally experienced and the lessons learned from these occurrences.

(more…)

HVAC Heat Energy Values – HVAC Technical

HVAC Heat Energy ValuesAir Conditioning and Heating HVAC Heat Energy Values - Heat is energy and when we produce heat we need to use energy in its production. There are natural methods for producing heat without burning or using fuels but these methods are not practical or available to the general populace for residential, commercial, and industrial use.

The production of heat, whether for residential, commercial, or industrial uses, uses energy, and energy costs money. It is thereby necessary to have reliable and proven methods of measuring the amount of heat produced using a specific quantity of energy. Employing these reliable and proven methods we can also use the data to determine the best methods of producing heat for homes, businesses, and industry. (more…)

Natural Gas Versus Propane | HVAC Heating Fuels

Natural Gas Versus Propane | HVAC Heating Fuels
Natural Gas Versus Propane | HVAC Heating Fuels - What is the best for you when choosing between either natural gas or propane? What is your heating system fuel supply? In some cases, you will not have a choice between the two. Having natural gas supplied to your home or business will require a natural gas pipeline near your home or business.

If there is a pipeline near your home and you do not have a meter, you can call the gas company. Most of the time, they will install the meter next to your home at no cost. However, it is always good to ask if they are going to charge you for installing a meter for use in your residence or business. (more…)

Changing a Standing Pilot Boiler to Electronic Ignition – Conversion Upgrade

Changing a Standing Pilot Boiler to Electronic Ignition

The Honeywell Y8610U Intermittent Pilot Retrofit Kit

Changing a Standing Pilot Boiler to Electronic Ignition - Conversion Upgrade - How many times have you spent time in the cold trying to light a pilot light on a standing pilot gas system?

I am certain if you are a service technician, then the previous sentence can be qualified with “How many frustrating times.” You go on a service call and find the old standing pilot gas system. Whether it is a water heater, furnace, or boiler, and you find the thermocouple is bad. Or some other reason that is keeping the pilot light from staying lit.

You clean the pilot burner and replace the thermocouple and walla…………..it lights and stays lit. The magical standing pilot works again. There is another option for you and your customer. And while it is not recommended in every situation it can help eliminate those pesky repeat service calls.

Calls where the pilot continues to go out for whatever reason? The sudden ghostly draft is one of the big reasons. Honeywell produces an electronic ignition retrofit kit that is ideal for residential and light commercial gas furnace systems. Gas systems that are eligible for an upgrade from standing pilot to electronic ignition (covers BTU ratings up to 270,000).

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

Changing a Standing Pilot Boiler to Electronic Ignition | Conversion Upgrade

The Y8610U Intermittent Pilot Retrofit Kit from Honeywell comes complete. It comes with a gas valve (Natural Gas to Propane (LP)) conversion kit in the box), ignition control, electronic spark assembly with flame sensor, ignition wire, and wiring harness. A seasoned technician will find wiring this a snap. Out of the box the gas valve can be used with either ½” or ¾” pipe so this will work with little changes made to the gas pipe.

From Standing Pilot to Electronic Ignition - Changing a Standing Pilot Boiler to Electronic Ignition

I recently upgraded my boiler from a standing pilot to this electronic ignition control. It reminded me of all those standing pilot furnaces and boilers out there that have been changed to electronic ignition by me when I was working in the field. I had recently purchased a new – old house (1920) that has a steam boiler in the basement. All summer, I kept thinking about upgrading the boiler to electronic ignition from a standing pilot.

Especially after a nasty springtime encounter with lighting the pilot light that reminded me of all the frustrating experiences. Finally, fall arrived, and it was time to start up the old boiler so we can have some heat. That is when I ordered the Y8610U Intermittent Pilot Retrofit Kit.

Throwing the Switch - Changing a Standing Pilot Boiler to Electronic Ignition

The intermittent pilot retrofit kit arrived, and immediately, I took it down to the boiler to make the new introduction. About an hour and a half later, I threw the switch for the main power. The boiler and the new electronic ignition module came to life by sparking. I couldn’t see it, but I could hear it.

About a second or two of sparking and I heard the pilot fire. A second later, the main burner’s fired and the old boiler (approximately 30 years old) got a taste of modern technology. Another hour in the basement was taking care of the boiler and doing annual boiler maintenance, and I can feel comfortable. Comfortable with the reliable heat this winter and the colder days of fall and spring.

Installation Made Easy by Honeywell

The manifold side of the gas valve is a ½ inch, but the kit comes with a ¾ inch flange if the manifold side of the gas valve requires ¾ inch. The gas supply side of the gas valve is a ¾ inch, but Honeywell includes a ¾ inch to ½ inch reducer bushing.

That makes it possible to use the include gas valve for either ¾ inch pipe or ½ inch black iron pipe. The most difficult part of the installation for me is usually not the piping or even the wiring but getting the pilot burner in the correct position to light the main burners.

The pilot burner is usually installed in a tight space, and you have to get it exactly right, so the main gas burners light right away when the main valve in the gas valve opens to feed gas to the main burners. We do not want any “whoosh” main burner ignition.

That means the pilot light is too far away from the main burner. That allows gas build-up, which can be dangerous. Make sure you get the pilot light in the recommended position per the manufacturer’s recommendations or guidelines.

Installation Tips

A few installation tips and features include the control only needs to be supplied with 24 VAC – no line voltage needed – you tap into the 24-volt transformer that should be with the boiler. Make sure you wire through all the safeties, so the control loses power when one of the safeties trips.

When the controller loses power, the burner shuts down. Always follow all the instructions when installing anything. Good luck with any future upgrades you decide to make concerning this retrofit ignition control kit.

Honeywell Y8610U6006 Gas Valve Intermittent Pilot Retrofit Kit Available here

High Performance HVAC

Changing a Standing Pilot Boiler to Electronic Ignition