Generators Serving Small Data Center | Critical Facilities - These generators serve a small data center giving the data center backup emergency power in the event of a loss of utility. Most data centers have redundant power from the utility and backup generators. In other words, the utility will provide two sources of utility power from two different power stations or sub-stations so if one source station loses power for whatever reason the system automatically transfers to the backup source of power or the other power or substation. (more…)
Cooling Tower Evaporation Cools Water | HVAC Technical - Cooling towers use the process of evaporation to cool or removes heat from the condenser water that was transferred to the water in the chiller condenser barrel. The heat is absorbed in the load in this case in a data center on a data center floor. The servers and electrical equipment produce a massive amount of sensible heat.
The heat is absorbed by computer room air conditioners or computer room air handlers. These systems, computer room air handlers, and air conditioners have chilled water coils. The chilled water originates at the chiller into the primary loop. The water circulates through the primary loop and makes its way into the secondary loops. (more…)
Data Center Perforated Tiles for Cooling Servers - There is a lot to consider with perforated tiles in data centers and depending on who you talk to you will get different answers. The server floor in a data center is typically built on a raised floor with cold air being pumped under the floor by large CRAH (Computer Room Air Handlers) or CRAC units (Computer Room Air Conditioners). (more…)
Computer Room Air Conditioner Units - also referred to as CRAC units are essential inside data centers where cooling is necessary for all the computer and electrical equipment most data centers utilize. It is important to keep the equipment cool to prevent overheating for some equipment. (more…)
HVAC Tip - Air Conditioner & Heat Pump Tips: Additional Helpful Hints:
Always change your air filter on a monthly basis
Make sure all your supply vents are open and unobstructed
Keep area clean around indoor unit especially the return grills
Keep outdoor units free of leaves, grass, and debris including trash cans and/or children's toys or playthings like small plastic pools or playhouses.
Additionally your service technician will appreciate you not planting holly bushes near the outside unit
Lastly have system serviced every six months - once for heating and once for cooling before the season starts
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.