Re:Hydronic baseboard heat (0 viewing) 
Residential Heating Systems Forum
Go to bottom Post Reply Favoured: 0
TOPIC: Re:Hydronic baseboard heat
#46
iamrichard (Admin)
Admin
Posts: 15
graph
User Online Now Click here to see the profile of this user
Gender: Male High Performance HVAC Location: Odessa, Ukraine Birthdate: 1965-01-01
Re:Hydronic baseboard heat 1 Month, 2 Weeks ago Karma: 0  
No, when you break open the system for a major upgrade or retrofit you will need to purge the entire system. If the near boiler piping was installed correctly you should have some drain valves and a gate valve installed in the piping on the return and the supply. This is where the purge for the whole systems needs to be done if those valves and drain valves were installed. The air purger is for operational purging and not for initial fill purging and this is what you will have to do when break the system open like you are planning.
 
Report to moderator   Logged Logged  
  The administrator has disabled public write access.
      Topics Author Date
    thread link
Hydronic baseboard heat
SG52 2008/03/25 01:00
    thread link
thread linkthread link Re:Hydronic baseboard heat
iamrichard 2008/03/26 04:37
    thread link
thread linkthread linkthread link Re:Hydronic baseboard heat
SG52 2008/03/27 03:07