Air Conditioners are big HVAC refrigerators. Air Conditioners and Heat Pumps use the HVAC refrigeration cycle to transfer heat from a place where it is not wanted (inside absorbing heat with the evaporator coil) to a place that makes no difference (outside using the condensing unit)(in the cooling cycle). The heart of any HVAC air conditioning, heat pump, or refrigeration system is the compressor which pumps the refrigerant through the HVAC air conditioning system. When the refrigerant leaves the compressor it is compressed and therefore a higher pressure than it was before it entered the compressor inside the condensing unit. This pressure remains constant (give or take under certain conditions) until it passes through the metering device where the pressure and temperature are reduced. This low pressure remains constant (again give or take under certain conditions) until it again reaches the compressor inside the condensing unit and is compressed again. To view a diagram of this cycle click here.

Place your mouse over the picture to zoom into the condenser coil cut-away

When you turn the air conditioner condensing unit off these pressures equalize within five minutes. The equalized pressure is often referred to as static pressure to HVAC professionals. The high side pressure on a hot day can be as high as 300 p.s.i. in some systems. If your HVAC system is not equipped with a delay timer and you turn the system on within five minutes of turning it off, the compressor inside the condenser must start against that higher pressure. That is not good for the compressor and could possibly damage it.

The HVAC air conditioner condensing unit compressor should not be started unless the air conditioning or heat pump system is at the static pressure. I have responded to calls where the air conditiong or heat pump condensing unit was not equipped with a delay timer and the air conditioning or heat pump condensing unit was inadvertently started before the pressures were allowed to become static. Often the compressor inside the condenser is locked up, the capacitor is shot, a fuse is blown, the compressor is damaged mechanically or electrically beyond repair, or a combination of any of these things mentioned.

HVAC Air Conditioner & Heat Pumps Condensing Unit Compressor Mechanics

If the homeowner is lucky, the only thing wrong is the capacitor or fuse. The capacitor for your compressor can be replaced for a minimal cost compared to replacing a compressor. If the compressor is locked up there is a chance that it can be unlocked (note the word chance). A hard start kit and a good rap with a hammer can sometimes do the trick. If this doesn't unlock the compressor then you will have to replace the compressor or the air conditioning or heat pump condensing unit. It is often in the homeowners best interest to replace the condensing unit.

Before this happens to you, call the company you often deal with to maintain and repair your HVAC system(s). Ask to speak with the HVAC service manager or HVAC technician that has worked on your HVAC equipment. Ask them if your condensing unit is equipped with a delay timer. They should be more than happy to answer your question............and if they are not sure ......check to see if the condensing unit is equipped with a delay timer. You may want to have the model number, serial number (for both the condenser and air handler), and type of thermostat you have. Most modern digital and programmable thermostats have delay timers built into them.

Move your mouse over the condenser main panel

New HVAC Air Conditioner Condensing Units & Heat Pumps Condensers Compressor Technology

For years compressors inside the condensing unit were sized to meet the highest load demand for whatever application they were serving. Even today, many compressors, located inside the condensing unit are sized in accordance with there highest load demand even though it is unlikely they will only be needed to run for full load conditions approximately 30-35% of the time. While many systems have worked just fine this way for many years they have not been very energy efficient. So even on a mild day these compressors run full blast even though the system may only require the compressor to run at 50% capacity to satisfy the demand. That creates problems with short cycling which causes premature wear, higher maintenance costs, and reduces total compressor life span.

HVAC Compressor manufacturers realize this and have developed new technologies to solve this problem. The first type of new HVAC compressor technology covered in this article is the two-stage scroll compressor. Inside this compressor is a plate with two precision holes drilled in it. One hole represents 80% capacity and the other hole represents 100% capacity. When the compressor is operating normally it is running at 80% capacity. With an increased demand this plate shifts allowing the compressor to handle the increased load. This process increases efficiency and decreases energy usage. The two-stage scroll is a variation of what some manufacturers have been trying to do but never had the technology to do it. Some manufacturers use compressors that have two-speed windings in them along with several controls to engage the higher speed winding when the demand calls for it. Other HVAC manufacturers put two compressors, one small and one big, in their units. These HVAC systems work just fine but are usually more expensive to manufacture. The new two-stage scroll offers you efficiency and energy savings without the added cost of these older HVAC systems. Remember there are more ways than one to calculate efficiency but there is only one way many of us calculate our energy savings and that is when we get the bill.  

The next HVACR development in new technology for compressors is the variable speed compressor. These compressors will only be available in the commercial market but it’s a good guess that it won’t be long before the compressor technology crosses over into residential systems. A variable speed compressor adds a whole new dimension to the efficiency factors for compressors. It also raises the bar on the type of controls used to control the drive that determines the speed of the compressor. Just to name a few of the factors needed to be taken into account to control this compressor are suction and discharge temperatures of the compressor along with the pressures, superheat and sub-cooling, and inside and outside ambient temperatures. Variable speed compressor systems will require a control algorithm that will process the inputs and send a desired output speed to the compressor based on the factors mentioned above. Variable speed compressor systems are complex and will require the attention of a properly trained HVAC technician to troubleshoot any problems that may arise with the system. Currently commercial refrigeration and air conditioning systems used loaders or unloaders and/or multi-compressor staging systems to meet demand. By and large these systems dominate the market now but when this new variable speed compressor technology takes off, these systems will most likely wither away being slowly replaced with the more efficient variable speed compressor systems.

One other note to consider in this age of new technology and higher HVAC energy efficient equipment being developed and manufactured, you can have the most energy efficient engine but if its in an old 60 or 70’s model car your efficiency is going to suffer. The same is true with HVAC systems. You have the most energy efficient compressor available on the market but if your duct work is leaky or your house or business is not properly insulated that compressor is wasted money. It is also important that when these systems are installed that they receive a proper commissioning and start-up to ensure they are working as designed. This typically involves checking out the whole HVAC system to make sure everything is working as efficiently as possible by a qualified HVAC technician. Just remember, as the cost of energy rises it becomes more and more critical to make sure the whole system works together as designed. Follow that little nugget of advice and you will see your energy bills decrease.

HVAC Air Conditioner or Heat Pump Condenser Coils

From time to time in commercial and residential HVAC there are HVAC units where it is more

Old Condenser Coils with several repairs and deemed by fair evaluation to be irrepairable.
heat pump condensing unit coils, heat pumps condenser coil leaking, air conditioner condenser coil repair
cost effective to change a major HVAC component than it is to replace the entire HVAC unit. Before this is done an evaluation should be performed on the potential financial risk of changing the major HVAC component versus changing the HVAC equipment. Consideration should be given to the age of the unit and chances of another major component failure in the near future. Age will also factor into the issue of actually finding a replacment part. Does the manufacturer even make the major component any longer or will you have to have one custom made? It becomes necessary to look at other major HVAC components in the HVAC system and check their condition. This often requires the attention of the owners of the equipment and someone trained (HVAC Professional) to make a fair evaluation and assessment of the other major components in the HVAC system. It is always a risk changing a major component because of the potential of another component failing in the near future and costing more than the cost of total HVAC unit replacement. Other considerations are efficiency of the old HVAC unit versus the efficiency of a new HVAC unit. What are the years to payback versus paying a higher utility bill for repairing and maintaining the old HVAC equipment? What is the maintenance and repair history of the old HVAC equipment in need of repair? Has the HVAC equipment in question been a headache with constant repair issues? After all these things are assessed one can make the best decision and that is replace the major HVAC component or replace the entire HVAC unit.

New condenser coils replacing old leaking irrepairable coils
new air conditioner condenser coils, air conditioning condenser coil replacement, heat pumps condensing unit coils

This brings up the issue and title of this article. Condenser coils. The above paragrapgh could apply to evaporator coils, compressors, or even replacing motors or variable frequency drives in the system. Sometimes coils can be repaired but other times they cannot. When you get a refrigerent leak in a condenser coil problems occur when applying heat to the the condenser or evaporator coils. Evaporator and condenser coils are designed to transfer heat. When an HVAC technician has to repair an evaporator or condenser coil they generally have to use a lot of heat to solder the hole in the evaporator or condenser coil. This heat is then transferred to other parts of the evaporator or condenser coil and that likely will cause factory made solder joints to loosen up. Before you know it another leak appears in another part of the condenser or evaporator coil and it's like a dog chasing his tail. The evaporator or condenser coil needs to be replaced or an evaluation for HVAC unit replacement needs to done for possible replacement versus major component retrofit.

 

High Performance HVAC

Condensing Units Page 1 | High Performance HVAC Site Map | Condensing Units Page 2 Top

 

High Performance HVAC

Your Resource for HVAC Condensing Unit Information

Recommended by High Performance HVAC
High Performance HVAC, condensing units, hvac condensers About Us | Site Map | Privacy Policy | Contact Us | ©2008 Richard D. Ashworth
 

High Performance HVAC Best Viewed with:

high performance hvac, condenser, condensing unit