Tired of LOUSY service? Try Angie’s List.

Tired of LOUSY service? Try Angie’s List.

Who's Online

We have 65 guests online
Tired of LOUSY service? Try Angie’s List.

Proper Humidity Levels

Having proper humidity levels in your home or business is important not only for your health but also in the amount of energy your HVAC systems use to keep you comfortable. If the humidity level in your home is high in the summer you will not feel cool. If the humidity level is low in the winter you will not feel warm when the thermostat is set at an average temperature. This will result in turning the HVAC thermostat up to compensate and you will use more energy to stay warm. A properly designed and installed system will keep the proper levels of humidity in your home or business and save you money on energy used by the HVAC System. For more information on humidity and the benefits of maintaining proper levels visit High Performance HVAC's Humidifier Page.

Before You Call

Before calling a heating and air conditioning company, check the following:
  • Check selections on thermostat. Ensure that it is set to the desired settings.
  • Check power supply. This can include a circuit breaker and or/a regular looking wall switch close to the indoor unit
  • Check for freezing up of units. If the unit is frozen turn it off. Check the filter(s) and supply vents to make sure they are not obstructed in any way. If you find no problems leave the unit turned off and call a service company.
Home Ask Mr HVAC Leaking Air from the Air Handler
Leaking Air from the Air Handler
Written by Richard   

High Performance HVAC Air Conditioning and Heating Answers

Leaking Air from the Air handler and Moisture on an Uninsulated Pipe

Leaking Air from the Air handler and Moisture on an Uninsulated Pipe

Dear Richard... my partner and I moved into a brand new mill conversion/rehab condo last year that we absolutely love, but after the summer was over, I went into the utility closet (where the air handler/gas furnace are) and noticed that there was copper corrosion crust/rust that had run down from the air handler (not sure from where, but somewhere fairly high up on the AHU). It had dried up, and didn't seem to be enough to run down the sides of the burner even--no streaks). This winter, though, I noticed that the suction line has a 1/4 inch gap below it (crappy install?), and that warm air was blowing out of it! There is a rubber gasket around it but still an open space around the copper pipe. I'm assuming that in the summer, cold air comes out of the same hole, and condensation must form on the first uninsulated 1/2 inch or so of the suction line, then run down leaving dried up copper oxide on the burner. It's also rusting the bolts on top of the burner. Plausible? How do I deal with the AHU? A little expanding foam? It would have to be replaced every time the panel comes off, though. Should this air be allowed to escape? It seems like a lot of air coming out. Thanks SO much, I have learned a lot from reading your articles! Also, what is a typical donation amount to your website?

Great to hear there are readers out there who appreciate my articles........I know they exist but i don't get many emails like this. It is also a good thing that you take the time to look at the equipment from time to time. It never hurts just to take a cursory look at your heating and air conditioning equipment from time to time. To answer your question, any air leaking from the air handler should be sealed. The air leak you describe is common. The suction line and liquid line which run from the condenser to the evaporator (inside the air handler) penetrate the cabinet and usually on most brands have a rubber gasket to prevent such leaks as you describe hear. Many times though the gasket dry rots or doesn't make a good seal for one reason or the other. The air leaking from this place where the suction line and liquid line penetrate the air handler cabinet is minimal but it is expending unnecessary energy and conditioning a space that usually requires a) no conditioning at all or b) already has conditioning supplied by design and not because of an air leak from the air handler. Seal up that hole with some good duct tape or the expanding foam will work to but be careful not to get too much inside the air handler lest you get some on the coil and cause a blackage in the evaporator coils which is worse than your existing problem..

Suction Line Insulation

The suction line is one of the pipes which penetrates the air handler cabinet. It is the larger of the two pipes which penetrates the air handler cabinet and it carries vapor refrigerant back to the condenser. This refrigerant vapor is cold and usually below the dew point. From reading some of the articles on this site you should know that anything that is below the dew point will sweat the moisture out of the air and this will cause moisture problems. Insulate that line and make sure it is sealed good to prevent moisture from forming on the pipe under the insulation. This is called creating a vapor barrier to prevent humidity in the air coming into contact with the pipe. You can get pipe insulation (usually called rubatex and its black) at your local hardware store in the plumbing section. Insulate that suction line to prevent moisture problems including rusting of the equipment. Good luck and keep an occassional eye on your HVAC equipment.


Leaking Air from the Air handler, Moisture Uninsulated Suction Line Pipe, air handler air leak

Trackback(0)
Comments (1)Add Comment
0
Thank you for this article!
written by Cameron, July 15, 2010
It helped answer my question! MY air handler in the attic was leaking a lot of cold air from the same spot as you described. I sealed it with foam and used Ducting tape(not duck tape). In addition I tape sealed a number of other leaks on the Air handler. If the Tape doesnt hold I will get some of the paste sealant and seal it properly. Anyway thank you again. smilies/grin.gif