Munchkin Hot Water Boiler Reviews Hot

 
Editor rating
 
3.8 User rating
 
1.4 (2)

Munchkin Hot Water Boiler Reviews


Munchkin offers small boilers for residential and light commercial use with efficiency AFUE ratings from 92% AFUE to 95% AFUE that range in capacities from 18,000 BTUh to 199,000 BTUh. Munchkin hot water boilers can be easily converted from natural gas to propane gas and use sealed combustion technology. Various features of selected Munchkin hot water boilers are:





  • Electronic spark ignition on Munchkin hot water boilers



  • Quiet operation on Munchkin hot water boilers



  • State of the Art control for Munchkin hot water boilers



  • Compact and durable stainless steel construction for Munchkin hot water boilers



  • Direct vent using schedule 40 PVC



  • Modulating firing rate for Munchkin hot water boilers


Munchkin boilers are made by Heat Transfer Products based out of Freetown, Massachusetts. Munchkin boilers can be ordered online directly from the manufacturer.




 


Munchkin hot water boiler reviews, Munchkin hot water boilers, hot water boiler reviews


 

Editor review

Munchkin Hot Water Boiler Reviews

Overall rating: 
 
3.8
Recommendation:
 
4.0
Quality:
 
4.0
Efficiency:
 
4.0
Reliability:
 
4.0
Installation:
 
3.0
Was this review helpful to you?
Yes No
Reviewed by Richard
August 14, 2009

Report this review
 
2 of 3 people found the following review helpful
Do you own a Munchkin Hot Water Boiler? If you own a Munchkin Hot Water Boiler make a review to let others know about Munchkin Hot Water Boiler.
 
 


User reviews

Average user rating from: 2 user(s)

Overall rating: 
 
1.4
Recommendation:
 
1.0   (2)
Quality:
 
1.0   (2)
Efficiency:
 
2.0   (2)
Reliability:
 
1.0   (2)
Installation:
 
2.0   (2)
 
Ratings (the higher the better)
Recommendation*
 
Quality*
 
Efficiency*
 
Reliability*
 
Installation*
 
Comments*
    Please enter the security code.
 
 

challenging for a heating professional to keep run

Overall rating: 
 
1.8
Recommendation:
 
1.0
Quality:
 
1.0
Efficiency:
 
3.0
Reliability:
 
1.0
Installation:
 
3.0
Was this review helpful to you?
Yes No
Reviewed by Steve
June 24, 2010
Comments (0)
Report this review
 
1 of 1 people found the following review helpful

I'm reporting on my own personal experience with my 140M Munchkin boiler, installed in my home about 5 yrs ago.

Efficiency on the Munchkin is, like most Modulating Condensing boilers, dependant more on a low return water temperature system design. Following that parameter, it appears on a par with a Triangle Tube Prestige boiler.

Reliability? OH MY GOD. This boiler has caused me more trouble than the most complicated systems than I've ever designed, installed, or maintained.

Year 1: No problems, simple, quiet operation.

Year 2: Beginning of Fault 09 Hell. Typified by the control board failing to see that the burner has, in fact, lit up. Disassembled, cleaned per instructions, flushed condensate trap and heat exchanger. Reassembled, Fault 09, lockout, hit reset, repeat perhaps 20-30 times while hearing the burner light off each time and watching the pretty flames on the burner cone that would not be recognized by the control board. Finally, the little green light comes on during an ignition trial and all's well for another year.

Year 3: Fault 09 Hell again. This time replaced the control board on recommendation from Tech Support "Sorry Mr. Rowe, your equipment's no longer covered by warranty, you'll have to shell out the $$$$ for the new board yourself" New board installed, Hit reset button for about 4 hours, until amazingly, the unit fired off w/o a hitch.

Year 3.5: Inducer blower flew apart internally. No heat....AGAIN....in my own home.....another $$$$ for a new blower assembly. Long talk w/ tech support "yes Mr. Rowe, we realize that the blower assembly design was changed (which I took to mean was found to be defective and revised), but you're out of warranty period and will need to pay for the new blower.

year 4: Fault 09 Hell again, ending with Fault 11 which signifies that the control board has gone beyond not recognizing the flame signal on ignition to now seeing a flame signal at all times, causing an instantaneous (rightly so!) lockout. Paid another $$$$ for a new control board. While spending the day resetting the control over and over, I spoke again with Tech Support trying to find out exactly WHAT's CAUSING THE FAILURES. Described the installation in depth, gave voltage readings, ohm readings etc. for nearly 2 hours. Suddenly, with no changes being made, the boiler lights off and all's supposed to be well. "Sorry Mr. Rowe, we understand that you've had a bad experience with our boiler, but we won't be covering any of this under warranty or offering you a replacement boiler. We do feel that the problem has now been corrected"

Today: My boiler's gone out....again....it's been acting up this week and finally went from Fault 09 Hell to Fault 11 Failure. Looks like if I want take a hot shower and want my family happy, I'll be shelling out yet another $$$$ for control board #3.

It's my belief, and has been my experience, that long before this point any other boiler manufacturer would have sent me a new boiler, fully covered under warranty along with a factory rep to commiserate and toss an apology in. Not so thusfar with HTP. I had expected them to man up and work with me to straighten this out. Since they have been unwilling to do so, My own belief is that no sane person should ever expose themselves to the possible nightmare that I've had!

It's quite sad, because the basic design seems sound, the piping is straightforward as long as you maintain proper flow through the boiler which usually means decoupling the boiler flow from the system flow. I'd love for Heat Transfer Products to work this out and be able to post glowing reviews of the Munchkin, and the company as a whole. At this point, the only thing that would change my mind would be a new, fulling functioning Munchkin.

 

Munchkin

Overall rating: 
 
1.0
Recommendation:
 
1.0
Quality:
 
1.0
Efficiency:
 
1.0
Reliability:
 
1.0
Installation:
 
1.0
Was this review helpful to you?
Yes No
Reviewed by edward west
February 14, 2010
Comments (0)
Report this review
 
0 of 0 people found the following review helpful

We have had the Munchkin M199 boiler system installed for approximately 6 years and have had nothing but problems with it. The blower was replaced within the first year, the igniter system was replaced within 2 years, the computer controller was replaced, etc. If fact, everything on the unit was replaced within 3 years and we have continued to have F09 faults for the last 3 years. We have never had hot water for more than 1 shower. Our gas bill has been extremely high for entire time since we installed the Munchkin unit. The local HVAC dealer/installer has not been able to solve the problems.

Editors comments - Extremely high gas bill? I would be interested in seeing the bills and posting them on this website to show people.

 
 
Powered by JReviews
Trackback(0)
Comments (1)Add Comment
0
needs careful install
written by Craig, October 30, 2009
This boiler was recommended and installed by a big Washington, D.C. company, JONES AND WOODS. DO NOT HIRE THEM. Lots of problems because basically they had no idea what they were doing and lied to me about all the experience they have had installing these units, as evidenced by the elementary mistakes they made. Finally got the Munchkin rep. on a site visit and he confirmed that they had left out MAJOR components, like the secondary circulator pump on the supply side, as plainly specified in the install manual. Learned lots from the rep, who was great, both about improvements in the Rev. 2 version of this unit as well recommendations: this little baby puts out LOTS of water as condensate, which must be directed back into the unit by having the exhaust pipe tilted back into the house. Steams outside like a locomotive in cold weather. The condensate, however, is HIGH ACID and must be neutralized with a kit as over time it will eat through even a cast iron drain. Condensate outlet hooked directly to a floor drain is a good idea. I'm using a standard plastic condensate pump to get the water up and over into a sink, and am worried that with the PH adjuster downstream of this pump, how long can the pump last? Also, how much net energy savings can there be, given the THREE electrical devices necesssary to run this moon unit? (2 circulators and the pump). :angry:

Write comment

busy
 
More articles :

» Generac 5504 17KW Propane/Natural Gas Home Automatic Standby Generator Review

Generac 5504 17,000 Watt Air Cooled Propane/Natural Gas Powered Home Automatic Standby Generator with Steel Enclosure (CARB Compliant) If you lost power and you had a Generac 5504 17KW standby generator you could run essential loads and depending on...

» Generac 5503 14KW Propane/Natural Gas Home Automatic Standby Generator Review

Generac 5503 14,000 Watt Air Cooled Propane/Natural Gas Powered Home Automatic Standby Generator with Steel Enclosure (CARB Compliant) The Generac 5503 14 KW Emergency Standby generator offers standby emergency power for the home and partial loads...

» Generac 5502 10KW Propane/Natural Gas Home Automatic Standby Generator Review

Generac 5502 10,000 Watt Air Cooled Propane/Natural Gas Powered Home Automatic Standby Generator with Steel Enclosure (CARB Compliant)The Generac 5502 10KW standby generator offers a little more juice (2KWs) the Generac 5501 which offers 8KW....

» Maytag or Rheem or

Maytag or Rheem or???To: richardSubject: highperformancehvac.com: Maytag vs. Rheem gas electric packaged heater ACFrom: SteveThis is an enquiry e-mail via http://highperformancehvac.comHi, We're trying to compare Maytag and Rheem gas/electric...

» Goodman/Amana Gas Manifolds are Dangerous!!!

The Goodman/Amana brands of gas furnaces have a quality issue that has gone unreported and will likely lead to a recall or serious accident. The gas nozzle threads leak gas into the unit and has been a known defect for the last 6 months but has...
Air Conditioner and Heating Systems Reviews